CEBORA S.p.A. 1 SOUND MIG 2035/M Pulse POWER SOURCE art. 285 SERVICE MANUAL 3.302.161 24/03/2004

Page 2 - CEBORA S.p.A. 2

CEBORA S.p.A. 10 2.9 - Set-up mode diagram. OFF O+R W E L D I N G M O D E O+R torch O+R Job 2 Spot (led C=on, leds L–M=off).

Page 3 - CEBORA S.p.A. 3

CEBORA S.p.A. 11 3 - MAINTENANCE WARNINGS ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIED PERSONNEL. BEFORE BEGINNING MAINTE

Page 4 - CEBORA S.p.A. 4

CEBORA S.p.A. 12 3.2.2 - Power source operation. NOTE  Operations preceded by this symbol refer to operator actions. ♦ Operations preceded by t

Page 5 - CEBORA S.p.A. 5

CEBORA S.p.A. 13 ♦ Display (G) indicates “dSp” if is the first time you enter in set-up mode, or the function code present last time you exit the s

Page 6 - CEBORA S.p.A. 6

CEBORA S.p.A. 14 3.3 - Troubleshooting. WARNINGS ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY QUALIFIED PERSONNEL. BEFORE REMOVING

Page 7 - CEBORA S.p.A. 7

CEBORA S.p.A. 15 ♦ Check the wiring between J3 power supply board (25) and terminals TP3(+) and TP4(-) of power board (26). ♦ With the power source

Page 8 - CEBORA S.p.A. 8

CEBORA S.p.A. 16 3.3.2 - Power source powered, control panel on, fan (24) stopped. FAN (24) TEST. Correct?  Power board (26), connector J2, term

Page 9 - CEBORA S.p.A. 9

CEBORA S.p.A. 17 3.3.3 - Power source powered, display and signals does not indicate the correct values. ERROR CODE TEST. Correct?  Upon start-u

Page 10 - CEBORA S.p.A. 10

CEBORA S.p.A. 18 3.3.4 - The start button produces no effect. TORCH TYPE RECOGNITION TEST. Correct?  Control board (27), connector J12, terminal

Page 11 - CEBORA S.p.A. 11

CEBORA S.p.A. 19 3.3.5 - Power source powered, no gas flows from the torch. SOLENOID VALVE (12) TEST. Correct?  Solenoid valve (12) terminals =

Page 12 - CEBORA S.p.A. 12

CEBORA S.p.A. 2 CONTENTS 1 - GENERAL INFORMATION...

Page 13 - CEBORA S.p.A. 13

CEBORA S.p.A. 20 MOTOR SPEED REFERENCE SIGNAL TEST WITH TRADITIONAL TORCH. Correct?  Control board (27), connector J12 terminal 24 (+) (or C79 l

Page 14 - CEBORA S.p.A. 14

CEBORA S.p.A. 21 ♦ Replace the wire feeder motor on the torch, or the entire torch. ♦ Replace the wire feeder motor (401). MOTOR SPEED REFERENCE S

Page 15 - CEBORA S.p.A. 15

CEBORA S.p.A. 22 3.3.7 - In open circuit operation, the output voltage is not regular. OPEN-CIRCUIT OUTPUT VOLTAGE TEST. Correct?  Power source

Page 16 - CEBORA S.p.A. 16

CEBORA S.p.A. 23 CURRENT TO PRIMARY CIRCUIT OF TRANSFORMER (30) TEST. Correct?  Control board (27), connector J4, terminals 3(+) – 4(-) = <0.1

Page 17 - CEBORA S.p.A. 17

CEBORA S.p.A. 24 3.3.8 - In resistive load operation, the output voltage is not regular. NOTE For the following tests set continuous “Mode” (led L

Page 18 - CEBORA S.p.A. 18

CEBORA S.p.A. 25 CURRENT ANALOG REFERENCE SIGNAL TEST. Correct?  Control board (27), connector J12, terminal 23(+) (or C86 left side) and connec

Page 19 - CEBORA S.p.A. 19

CEBORA S.p.A. 26 3.3.9 - Arc difficult to strike, the arc goes out immediately after lighting. “Hot-Start” and “Soft Start” functions are adjustab

Page 20 - CEBORA S.p.A. 20

CEBORA S.p.A. 27 3.3.11 - In synergic mode, the welding quality is not satisfactory, the wire speed is not suited to the output current. NOTE The

Page 21 - CEBORA S.p.A. 21

CEBORA S.p.A. 28 3.4 - Error codes and alarm signals. 3.4.1 - 01 - Internal RAM error. 3.4.2 - 02 - EEPROM error. Block due to software error. Re

Page 22 - CEBORA S.p.A. 22

CEBORA S.p.A. 29 3.4.7 - 30 - Incorrect setting of the minimum current threshold on the control board (27). MINIMUM THRESHOLD CURRENT SETTING. Corr

Page 23 - CEBORA S.p.A. 23

CEBORA S.p.A. 3 3.4 - Error codes and alarm signals...

Page 24 - CEBORA S.p.A. 24

CEBORA S.p.A. 30 Check the wiring between connector J4 of control board (27) and current transducer (33), and the power wiring between the “cathode”

Page 25 - CEBORA S.p.A. 25

CEBORA S.p.A. 31 − Make sure that the thermostat mounted on the diode group (56) is properly assembled and functioning correctly; its contact must b

Page 26 - CEBORA S.p.A. 26

CEBORA S.p.A. 32 4 - COMPONENTS LIST 4.1 - Power source art. 285 : see file ESP285.pdf enclosed at the end of the manual. 4.2 - Components table:

Page 27 - CEBORA S.p.A. 27

CEBORA S.p.A. 33 5 - ELECTRICAL DIAGRAMS 5.1 - Power source art. 285 : see file SCHE285.pdf enclosed at the end of the manual. 5.2 - Waveforms.

Page 28 - CEBORA S.p.A. 28

CEBORA S.p.A. 34 5.2.3 - Wire feeder motor (401) voltage during correct braking (par. 3.3.10). 5.2.4 - Wire feeder motor (401) voltage during i

Page 29 - CEBORA S.p.A. 29

CEBORA S.p.A. 35 5.3 - Filter board (47) code 5.602.164. 5.3.1 - Topographical drawing. 5.3.2 - Connector table. Connector Terminals Function

Page 30 - CEBORA S.p.A. 30

CEBORA S.p.A. 36 5.5 - Power board (26) code 5.602.162. 5.5.1 - Topographical drawing. 5.5.2 - Connector table. Connector Terminals Function

Page 31 - CEBORA S.p.A. 31

CEBORA S.p.A. 37 5.6 - Driver-igbt board code 5.600.757. 5.6.1 - Topographical drawing. 5.6.2 - Connector table. Connector Terminals Function

Page 32 - CEBORA S.p.A. 32

CEBORA S.p.A. 38 5.7.2 - Connector table. Conn. Terminals Function J1 1 - 2 start command input from traditional torch button. J2 1(+) -

Page 33 - CEBORA S.p.A. 33

CEBORA S.p.A. 39 5.8 - Panel board (41) code 5.602.178. 5.8.1 - Topographical drawing. 5.8.2 - Connector table. Conn. Terminals Function.

Page 34 - CEBORA S.p.A. 34

CEBORA S.p.A. 4 1 - GENERAL INFORMATION 1.1 - Introduction. The purpose of this manual is to train personnel assigned to carry out maintenance on

Page 35 - CEBORA S.p.A. 35

CEBORA S.p.A. 40 5.9 - Push-pull board (43) code 5.602.171. 5.9.1 - Topographical drawing. 5.9.2 - Connector table. Conn. Terminals Functi

Page 36 - CEBORA S.p.A. 36

CEBORA S.p.A. 41 5.10 - Snubber board (58) code 5.602.166. 5.10.1 - Topographical drawing. 5.10.2 - Connector table. Conn. Terminals Functio

Page 37 - CEBORA S.p.A. 37

CEBORA S.p.A. 5 2 - SYSTEM DESCRIPTION 2.1 - Introduction. The SOUND MIG 2035/M Pulse is a system for MIG/MAG pulsed synergic, MIG/MAG non-pulsed

Page 38 - CEBORA S.p.A. 38

CEBORA S.p.A. 6 The diode group (56) is made up of two diodes connected to a shared cathode, and provides a positive output voltage with regard to th

Page 39 - CEBORA S.p.A. 39

CEBORA S.p.A. 7 2.4 - Programming power source art. 285 (firmware upgrade). The control board (27) contains the main microprocessor of the power sou

Page 40 - CEBORA S.p.A. 40

CEBORA S.p.A. 8 2.8 - Programs tables. 2.8.1 - Conventional non synergic programs (ver. H06). Materiale / Material∅filo ∅wireGas Torch Art. 124

Page 41 - CEBORA S.p.A. 41

CEBORA S.p.A. 9 2.8.3 - Pulsed synergic programs (ver. P03). Materiale / Material∅filo ∅wireGas Torch Art. 1242Torch Art. 2003Prg. N°Ferro / Iro